Improvement, performance test and evaluation for Schmidt–Boelter gage
-
-
Abstract
A kind of the small size Schmidt–Boelter gage was improved for measuring dynamic heat flux in the continuous variable attack angle test in the conventional hypersonic wind tunnel. The Schmidt–Boelter gage improved was statically calibrated and dynamically tested by the heat flux calibration devices. The test results show that the sensitivity coefficient is 57.67 μV·kW−1·m2, the response time is 27 ms, the cut-off frequency is 26 Hz and the gage range coverage is 1–130 kW/m2. Then the quantitative relation between the continuous variable attack angle velocity and the maximum test error was established based on the feature response time constant. And referring to the heat flux measured in the step variable attack angle test, the maximum velocity of the continuous variable attack angle supported by the gage was evaluated within a certain margin of error.
-
-