张朋勇, 郑丹丹, 徐天室, 张力新, 胡鹤鸣. 超声流量计探头对流场及其测量性能影响研究[J]. 实验流体力学, 2011, 25(3): 60-65. DOI: 10.3969/j.issn.1672-9897.2011.03.014
引用本文: 张朋勇, 郑丹丹, 徐天室, 张力新, 胡鹤鸣. 超声流量计探头对流场及其测量性能影响研究[J]. 实验流体力学, 2011, 25(3): 60-65. DOI: 10.3969/j.issn.1672-9897.2011.03.014
ZHANG Peng-yong, ZHENG Dan-dan, XU Tian-shi, ZHANG Li-xin, HU He-ming. Study on the influence of ultrasonic probes on flow field and measurement performance of ultrasonic flowmeter[J]. Journal of Experiments in Fluid Mechanics, 2011, 25(3): 60-65. DOI: 10.3969/j.issn.1672-9897.2011.03.014
Citation: ZHANG Peng-yong, ZHENG Dan-dan, XU Tian-shi, ZHANG Li-xin, HU He-ming. Study on the influence of ultrasonic probes on flow field and measurement performance of ultrasonic flowmeter[J]. Journal of Experiments in Fluid Mechanics, 2011, 25(3): 60-65. DOI: 10.3969/j.issn.1672-9897.2011.03.014

超声流量计探头对流场及其测量性能影响研究

Study on the influence of ultrasonic probes on flow field and measurement performance of ultrasonic flowmeter

  • 摘要: 超声流量计探头安装位置会对其测量产生影响.对DN500超声流量计在探头全伸位置安装时的流场以及对超声流量计测量性能的影响进行了数值仿真研究.仿真结果表明,入口速度为0.3~8m/s时,由于探头伸入管道而造成超声流量计的测量误差为-1.25%~-1.9%,且随着入口速度增大,测量误差逐渐增大;当速度达到一定范围后,测量误差基本趋于稳定.在此基础上通过流场分析指出,由于探头附近区域存在回流,造成各声道线平均速度减小,导致测得的流量值偏小,因此测量误差为负.

     

/

返回文章
返回