  • 摘要: 薄膜电阻温度计是高超声速测热试验中一种常用的传感器,多用于激波风洞中.改进薄膜电阻温度计测热数据的后处理方法,分析其原理性误差,提出修正方法,可以进一步提高热流测量精度,为防热设计提供可靠数据.应用三维热传导理论,考虑热流和温升的耦合影响,计算了气动加热条件下薄膜电阻温度计结构温升情况,得到了铂层内的温度分布规律,并与一维半无限简化理论得到的薄膜电阻温度计表层温度相互对比,得到了模型简化带来的原理性误差;建立了由表面温升计算表面热流的导热反问题计算方法,与经典的Cook-Felderman处理公式和热电模拟网络处理方法相互对比,提出了修止热流值的方法,为提高热流测量精度提供了一种可行的手段.

     

/