低速增压风洞压力测量系统设计与误差分析

张伟, 戴景民, 徐龙金, 王萍

张伟, 戴景民, 徐龙金, 王萍. 低速增压风洞压力测量系统设计与误差分析[J]. 实验流体力学, 2009, 23(3): 95-99,103. DOI: 10.3969/j.issn.1672-9897.2009.03.020
引用本文: 张伟, 戴景民, 徐龙金, 王萍. 低速增压风洞压力测量系统设计与误差分析[J]. 实验流体力学, 2009, 23(3): 95-99,103. DOI: 10.3969/j.issn.1672-9897.2009.03.020
ZHANG Wei, DAI Jing-min, XU Long-jin, WANG Ping. Design and error analysis on pressure measurement system of low speed pressurized wind tunnel[J]. Journal of Experiments in Fluid Mechanics, 2009, 23(3): 95-99,103. DOI: 10.3969/j.issn.1672-9897.2009.03.020
Citation: ZHANG Wei, DAI Jing-min, XU Long-jin, WANG Ping. Design and error analysis on pressure measurement system of low speed pressurized wind tunnel[J]. Journal of Experiments in Fluid Mechanics, 2009, 23(3): 95-99,103. DOI: 10.3969/j.issn.1672-9897.2009.03.020

低速增压风洞压力测量系统设计与误差分析

详细信息
  • 中图分类号: 11-5266/V

Design and error analysis on pressure measurement system of low speed pressurized wind tunnel

  • 摘要: 低速增压风洞的雷诺数能够达到8.5×106,但与常规的风洞相比它的内部压力可高达0.4MPa.为此,设计了一套满足增压状态下的高精度风洞压力测量系统.系统采用耐压的PSI8400设备进行压力测量.通过模拟压力工作环境和分析测量的数据,找到压力风洞压力测量误差的主要原因是温漂、时漂、零偏置和压力效应.据此,采取了5点校准、正负校准等方法,消除了它的影响.通过与压力标准PCU比对和验证,这套压力测晕系统的精度优于0.05%.因此这套压力测量系统可以在压力风洞中进行多种高精度的测量.这套测压系统已在增压风洞的轴向静压梯度测量中得到应用,解决了压力风洞中流场校测的测量问题.
计量
  • 文章访问数:  123
  • HTML全文浏览量:  30
  • PDF下载量:  10
  • 被引次数: 0
出版历程
  • 刊出日期:  2009-02-28

目录

    /

    返回文章
    返回
    x 关闭 永久关闭