纯净空气来流下的超声速燃烧实验装置及其初步实验结果

宋文艳, 王靛, 陈亮, 乐嘉陵

宋文艳, 王靛, 陈亮, 乐嘉陵. 纯净空气来流下的超声速燃烧实验装置及其初步实验结果[J]. 实验流体力学, 2007, 21(1): 1-6. DOI: 10.3969/j.issn.1672-9897.2007.01.001
引用本文: 宋文艳, 王靛, 陈亮, 乐嘉陵. 纯净空气来流下的超声速燃烧实验装置及其初步实验结果[J]. 实验流体力学, 2007, 21(1): 1-6. DOI: 10.3969/j.issn.1672-9897.2007.01.001
SONG Wen-yan, WANG Dian, CHEN Liang, LE Jia-ling. Experimental facility and preliminary results for supersonic combustion in clean air inflow[J]. Journal of Experiments in Fluid Mechanics, 2007, 21(1): 1-6. DOI: 10.3969/j.issn.1672-9897.2007.01.001
Citation: SONG Wen-yan, WANG Dian, CHEN Liang, LE Jia-ling. Experimental facility and preliminary results for supersonic combustion in clean air inflow[J]. Journal of Experiments in Fluid Mechanics, 2007, 21(1): 1-6. DOI: 10.3969/j.issn.1672-9897.2007.01.001

纯净空气来流下的超声速燃烧实验装置及其初步实验结果

详细信息
  • 中图分类号: 51-1499/V

Experimental facility and preliminary results for supersonic combustion in clean air inflow

  • 摘要: 采用电阻加热的连续式实验设备,在燃烧室进口气流为高温纯净空气、马赫数Ma=2、总温Tt=1000K,总压Pt=0.8MPa条件下,进行了不同当量油气比的氢和乙烯燃料的超声速燃烧室直连式实验.采用从壁面垂直于主流喷射燃料和以氢作为先锋火焰,实现了乙烯燃料的可靠点火和稳定燃烧.实验测量了燃烧室的壁面压力、空气流量、燃料喷射压力、喷管进口总温等参数,并拍摄了燃烧室出口火焰.本文实验采用的电阻加热设备具有实验介质无污染、稳定运行时间长、工作性能稳定、成本低、操作简单等优点,其主要部件电阻加热器出口的最高温度可达600~1000K,对应的流量为1.5~0.73kg/s、加热器功率为750KW.
计量
  • 文章访问数:  118
  • HTML全文浏览量:  33
  • PDF下载量:  5
  • 被引次数: 0
出版历程
  • 刊出日期:  2006-12-31

目录

    /

    返回文章
    返回
    x 关闭 永久关闭