  • 摘要: 三维粒子成像测速(PIV)的透视成像分析方法中,在运用体积光照明并从多个不同光轴方向用多台照相机或摄像机同时获得PIV图像后,根据多幅不同光轴的PIV图像的透视性质,运用物点三维定位的透视成像定位原理和方法,可通过找出各透视面上像点所对应的透视射线的交点来确定相应粒子的三维位置.问题在于,尽管粒子所在位置上必然存在各像点相应的透视射线的交点,但反过来,相应的透视射线的交点上却未必存在着真实的粒子.换言之,示踪粒子与其像点相应的透视射线相交的交点间一般并不存在一一对应的关系.本文讨论了在给定透视中心和透视平面位置的条件下,由多幅不同光轴的PIV图像上的粒子的透视像点来确定粒子物点是否存在意义上的可确定性,并讨论了PIV图像上粒子像斑密度、尺度及其中心测量精度对粒子物点可确定概率的影响.