应用热线风速仪对熔喷流场的温度速度同步测量方法

王鑫, 杨颖, 马云驰, 麻伟巍

王鑫, 杨颖, 马云驰, 麻伟巍. 应用热线风速仪对熔喷流场的温度速度同步测量方法[J]. 实验流体力学, 2016, 30(1): 91-96. DOI: 10.11729/syltlx20150068
引用本文: 王鑫, 杨颖, 马云驰, 麻伟巍. 应用热线风速仪对熔喷流场的温度速度同步测量方法[J]. 实验流体力学, 2016, 30(1): 91-96. DOI: 10.11729/syltlx20150068
Wang Xin, Yang Ying, Ma Yunchi, Ma Weiwei. Research on synchronous measurement of temperature and velocity in melt-blowing flow field based on hot-wire anemometer[J]. Journal of Experiments in Fluid Mechanics, 2016, 30(1): 91-96. DOI: 10.11729/syltlx20150068
Citation: Wang Xin, Yang Ying, Ma Yunchi, Ma Weiwei. Research on synchronous measurement of temperature and velocity in melt-blowing flow field based on hot-wire anemometer[J]. Journal of Experiments in Fluid Mechanics, 2016, 30(1): 91-96. DOI: 10.11729/syltlx20150068

应用热线风速仪对熔喷流场的温度速度同步测量方法

基金项目: 

中央高校基本科研业务费专项基金

国家自然科学基金面上项目

详细信息
  • 中图分类号: 11-5266/V

Research on synchronous measurement of temperature and velocity in melt-blowing flow field based on hot-wire anemometer

  • 摘要: 热线风速仪是将速度信号转化为电信号的测速设备,在流场测量方面应用广泛.同步测量方法的实验系统主要包括自加热设备、Dantec热线风速仪和二维探头.本文介绍了同步测量方法,进行了变温度流场的数据处理.结果表明,在变温度流场中必须进行温度速度的同步测量,关键在于在对应温度下标定速度,另外在处理变温度流场数据时要代入变温度标定系数.实验结果证明速度和温度分布可以通过同步测量方法快速有效地获得.
  • 期刊类型引用(4)

    1. 王烨,胡佳志,管国祥. 变温度场下提高热线探针标定精度的方法(英文). Journal of Measurement Science and Instrumentation. 2023(02): 164-173 . 百度学术
    2. 李云鹏,李若洁,张俊芳,姚仁太. 环境风洞中基于热线和冷线结合的风温瞬态同步测量技术研究. 四川环境. 2021(04): 217-223 . 百度学术
    3. 饶剑,马国鹭,宋子军,赵涌,赵登峰,何林. 基于微粒示踪的燃烧尾喷流速场测量方法研究. 光学技术. 2021(05): 577-581 . 百度学术
    4. 张云伟,全永凯. 热线风速仪非标定工况下测试修正方法研究. 推进技术. 2018(09): 2094-2101 . 百度学术

    其他类型引用(5)

计量
  • 文章访问数:  123
  • HTML全文浏览量:  37
  • PDF下载量:  9
  • 被引次数: 9
出版历程
  • 刊出日期:  2016-02-24

目录

    /

    返回文章
    返回
    x 关闭 永久关闭