CAO Chuan-jun, HUANG Guo-ping, LIANG De-wang. The pressure measurement of millimeter level plane cascade using pressure sensitive paint[J]. Journal of Experiments in Fluid Mechanics, 2010, 24(1): 68-73. doi: 10.3969/j.issn.1672-9897.2010.01.013
Citation: CAO Chuan-jun, HUANG Guo-ping, LIANG De-wang. The pressure measurement of millimeter level plane cascade using pressure sensitive paint[J]. Journal of Experiments in Fluid Mechanics, 2010, 24(1): 68-73. doi: 10.3969/j.issn.1672-9897.2010.01.013

The pressure measurement of millimeter level plane cascade using pressure sensitive paint

doi: 10.3969/j.issn.1672-9897.2010.01.013
  • Publish Date: 2010-01-01
  • A novel non-contact pressure measurement system of pressure sensitive paint (PSP) was established. One set of test section of millimeter level plane cascade which can be dis-assembled was designed. The surface pressure of blade suction side with and without tip clearance was measured using PSP technology for the first time. The results show that, because of tip clearance, the blade pressure side gas leaks into the suction side through tip clearance and the surface pressure of the top of blade suction side is bigger than it of the bottom. Contrast with the condition of no tip clearance, leakage has significant impact on the pressure on one third of the blade span of suction side, but little on the bottom of suction side.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (134) PDF downloads(8) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return