Volume 34 Issue 4
Aug.  2020
Turn off MathJax
Article Contents
LIU Xiang, XIONG Jian, MA Husheng, et al. The calibration and image post-processing method research of temperature-sensitive paint[J]. Journal of Experiments in Fluid Mechanics, 2020, 34(4): 53-61. doi: 10.11729/syltlx20190054
Citation: LIU Xiang, XIONG Jian, MA Husheng, et al. The calibration and image post-processing method research of temperature-sensitive paint[J]. Journal of Experiments in Fluid Mechanics, 2020, 34(4): 53-61. doi: 10.11729/syltlx20190054

The calibration and image post-processing method research of temperature-sensitive paint

doi: 10.11729/syltlx20190054
  • Received Date: 2019-04-25
  • Rev Recd Date: 2020-06-02
  • Publish Date: 2020-08-25
  • Temperature-sensitive Paint (TSP) calibration error is an important error source in the TSP experimental technique. Based on the domestic 615/EP TSP, the effects of some calibration technical details including the CCD exposure time, image average quantity, noise level, image definition and analog-to-digital (A/D) conversion digit on the calibration precision are studied. The research results show that, the image noise level has a significant effect on the calibration precision. In an image region of low noise level, the image definition and the image average quantity have less significant influence on the calibration precision. In order to obtain high-precision calibration results, the image gray should exceed 32% of the CCD full-well capacity for the Hamamatsu CCD camera, and the tunnel test and calibration test should have the same number of digits for the image A/D conversion.
  • loading
  • [1]
    KOLODNER P, TYSON J A. Microscopic fluorescent imaging of surface temperature profiles with 0.01℃ resolution[J]. Applied Physics Letters, 1982, 40(9):782-784. doi: 10.1063/1.93258
    [2]
    KOLODNER P, TYSON J A. Remote thermal imaging with 0.7μm spatial resolution using temperature-dependent fluorescent thinflims[J]. Applied Physics Letters, 1983, 42(1):117-119. doi: 10.1063/1.93766
    [3]
    LANG W, GARDNER A D, MARIAPPAN S, et al. Boundary-layer transition on a rotor blade measured by temperature-sensitive paint, thermal imaging and imagederotation[J]. Experiments in Fluids, 2015, 56(6):1-14. doi: 10.1007/s00348-015-1988-5
    [4]
    KLEIN C, HENNE U. Combination of temperature sensitive paint and carbon nanotubes for transition detection[R]. AIAA 2015-1558, 2015.
    [5]
    HORAGIRI T, NAGAI H, SACHS W, et al. Development of temperature-sensitive paint with high performance and responsibility for aerodynamic heating measurement[R]. AIAA 2014-1408, 2014.
    [6]
    NAGAI H, OHMI S, ASAI K, et al. Effect of temperature-sensitive-paint thickness on global heat transfer measurement in hypersonicflow[J]. Journal of Thermophysics and Heat Transfer, 2008, 22(3):373-381. doi: 10.2514/1.34152
    [7]
    NAGAI H, SWAMURA R, ASAI K. Experimental study of heat transfer measurement using temperature-sensitive paint for high-temperature application in hypersonic flow[R]. AIAA 2011-850, 2011.
    [8]
    OZAWA H, LAURENCE S J, SCHRAMM J M, et al. Fast-response temperature-sensitive-paint measurements on a hypersonic transitioncone[J]. Experiments in Fluids, 2014, 56(1):1-13.
    [9]
    WATKINS A N, LEIGHTY B D, LIPFORD W E, et al. Pressure-and temperature-sensitive paint at 0.3-m transonic cryogenic tunnel[R]. NASA/TM-2015-218801, 2015.
    [10]
    KURITS I, LEWIS M J. Global temperature-sensitive paint system for heat transfer measurements in long-duration hypersonicflows[J]. Journal of Thermophysics and Heat Transfer, 2009, 23(2):256-266. doi: 10.2514/1.39926
    [11]
    KURITS I, NORRIS J, BHANDARI P. Temperature-sensitive paint calibration methodology developed at AEDC tunnel 9[R]. AIAA 2011-851, 2011.
    [12]
    NAGAYAMA T, NAGAI H, TANNO H, et al. Visualization of hypersonic boundary layer transition on elliptic cone in high enthalpy shock tunnel with temperature-sensitive paint[R]. AIAA 2016-0358, 2016.
    [13]
    FEY U, EGAMI Y, ENGLER R. High Reynolds number transition detection by means of temperaturesensitive paint[R]. AIAA 2006-514, 2006.
    [14]
    EGAMI Y, FEY U, QUEST J. Development of new two-component TSP for cryogenic testing[R]. AIAA 2007-1062, 2007.
    [15]
    EGAMI Y, KLEIN C, HENNE U, et al. Development of a highly sensitive temperature-sensitive paint for measurements under ambient (0-60℃) conditions[R]. AIAA 2009-1075, 2009.
    [16]
    KLEIN C. Development of a highly sensitive temperature-sensitive paint for measurements under cryogenic temperatures (100~160 K) conditions[R]. AIAA 2016-0650, 2016.
    [17]
    VLADIMIR M, ANATOLY O, VLADIMIR R. Temperature sensitive paint (TSP) for heat transfer measurement in short duration wind tunnels[C]//Proc of International Congress on Instrumentation in Aerospace Simulation Facilities. 2003.
    [18]
    董艳丽, 孙晶, 范薇, 等.发光温敏漆的制备及其温度猝灭特性研究[J].光学与光电技术, 2011, 9(6):93-96. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gxygdjs201106022

    DONG Y L, SUN J, FAN W, et al. Study on temperature quenching characteristics and preparation of luminescent temperature sensitive paint[J]. Optics & Optoelectronic Technology, 2011, 9(6):93-96. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=gxygdjs201106022
    [19]
    尚金奎, 王鹏, 陈柳生, 等. TSP技术在转捩检测中的应用研究[J].空气动力学学报, 2015, 33(4):464-469. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=kqdlxxb201504004

    SHANG J K, WANG P, CHEN L S, et al. Application research of TSP technique in transitiondetection[J]. Acta Aerodynamica Sinica, 2015, 33(4):464-469. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=kqdlxxb201504004
    [20]
    张扣立, 常雨, 孔荣宗, 等.温敏漆技术及其在边界层转捩测量中的应用[J].宇航学报, 2013, 34(6):860-865. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yhxb201306017

    ZHANG K L, CHANG Y, KONG R Z, et al. Temperature sensitive paint technique and its application in measurement of boundary layertransition[J]. Journal of Astronautics, 2013, 34(6):860-865. http://www.wanfangdata.com.cn/details/detail.do?_type=perio&id=yhxb201306017
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(19)

    Article Metrics

    Article views (296) PDF downloads(28) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return