Lin Xin, Zeng hui, Peng Jinlong, et al. Atomic emission spectroscopy diagnostics for leak detection of cooling water in a low-enthalpy arc heater[J]. Journal of Experiments in Fluid Mechanics, 2019, 33(5): 81-86. doi: 10.11729/syltlx20180174
Citation: Lin Xin, Zeng hui, Peng Jinlong, et al. Atomic emission spectroscopy diagnostics for leak detection of cooling water in a low-enthalpy arc heater[J]. Journal of Experiments in Fluid Mechanics, 2019, 33(5): 81-86. doi: 10.11729/syltlx20180174

Atomic emission spectroscopy diagnostics for leak detection of cooling water in a low-enthalpy arc heater

doi: 10.11729/syltlx20180174
  • Received Date: 2018-11-09
  • Rev Recd Date: 2019-01-30
  • Publish Date: 2019-10-25
  • Arc-heated facilities play an important role in the development of thermal protection materials and heat shield structures for entry vehicles. Owing to the intensive heat fluxes generated by the arc root at the electrode surface, the erosion of the electrode is inevitable and there exists a risk of the cooling water leaking from the electrodes due to the accumulation erosion of the electrode material. It is well acknowledged that the arc heater can be severely damaged due to the late leak detection. Therefore, the development of fast response and accurately quantitative diagnostic techniques for leak detection of cooling water in an arc heater would be highly beneficial. Due to the harsh conditions inside the arc heater, especially for the low-enthalpy arc heater (total enthalpy range:2~12 MJ/kg), choices for the diagnostic methods are limited. Optical emission spectroscopy (OES) is a powerful tool to probe atoms and molecules which has been used in many areas such as chemical kinetics, non-equilibrium radiation, and so on. This paper presents an experimental investigation of the application of OES in the leak detection of cooling water for a low-enthalpy arc-heated wind tunnel (FD-04). According to the spectral characteristics of the high-temperature flow field in the FD-04 arc heater, the 777.19 nm emission spectral line of the atomic oxygen (O777.19) is utilized for monitoring the operating status and determining the leakage of the cooling water. A relative intensity determination method for the O777.19 emission is proposed and water leakage failures are successfully diagnosed under two test conditions at total enthalpy values of 11.6 and 9.8 MJ/kg. A solution is proposed that the diagnostic technology keeps high enough sensitivity for multiple total enthalpy conditions. This work demonstrates the potential of using the OES technique for leak detection of cooling-water in a low-enthalpy arc-heated facility.
  • loading
  • [1]
    Grinstead J H, Porter B J, Carballo J E. Flow property measurement using laser-induced fluorescence in the NASA ames interaction heating facility[R]. AIAA-2011-1091, 2011.
    [2]
    Lin X, Chen L Z, Zeng H, et al. High enthalpy arc-heated plasma flow diagnostics by tunable diode laser absorption spectroscopy[C]//Proceedings of the Fourth International Symposium on Laser Interaction with Matter. 2017.
    [3]
    Dubreus T M, Sheeley J M, Stewart J H. Development of a mid-pressure arc-heated facility for hypersonic vehicle testing[R]. AIAA-2010-1732, 2010.
    [4]
    Gülhan A, Esser B, Koch U. Experimental investigation of reentry vehicle aerothermodynamic problems in arc-heated facilities[J]. Journal of Spacecraft and Rockets, 2001, 38(2):199-206. doi: 10.2514/2.3670
    [5]
    Smith R K, Wagner D A, Cunningham Dr J. A survey of current and future plasma arc-heated test facilities for aerospace and commercial applications[R]. AIAA-1998-146, 1998.
    [6]
    欧东斌, 陈连忠, 董永晖, 等.大尺寸结构部件电弧风洞烧蚀试验技术[J].空气动力学学报, 2015, 33(5):661-666. http://d.old.wanfangdata.com.cn/Periodical/kqdlxxb201505013

    Ou D B, Chen L Z, Dong Y H, et al. Ablation test technique of large scale structure component in arc-heated wind tunnel[J]. Acta Aerodynamica Sinica, 2015, 33(5):661-666. http://d.old.wanfangdata.com.cn/Periodical/kqdlxxb201505013
    [7]
    Felderman E J, Chapman R, Jacocks J L, et al. High-pressure arc heater development and modeling-status and requirements[J]. Journal of Propulsion and Power, 1996, 12(6):1044-1052. doi: 10.2514/3.24142
    [8]
    Coulombe S, Meunier J L. Arc-cold cathode interactions-parametric dependence on local pressure[J]. Plasma Sources Sci Technol, 1997, 6:508-517. doi: 10.1088/0963-0252/6/4/008
    [9]
    Essiptchouk A M, Sharakhovsky L I, Marotta A A. Working conditions of a copper cathode with minimum erosion[J]. Plasma Sources Science and Technology, 2003, 12:501-507. doi: 10.1088/0963-0252/12/4/301
    [10]
    Webb B T, Sheeley J M. Investigation of the effects of shear on arc-electrode erosion using a modified arc-electrode mass loss model[R]. AIAA-2017-0217, 2017.
    [11]
    Essiptchouk A M, Sharakhovsky L I, Marotta A A. The effect of surface electrode temperature on cold electrode erosion behaviour[J]. Plasma Sources Science and Technology, 2007, 16:1-6. doi: 10.1088/0963-0252/16/1/001
    [12]
    Kim S. Development of tunable diode laser absorption sensors for a large-scale arc-heated-plasma wind tunnel[D]. California: Stanford University, 2004.
    [13]
    Winter M W, Prabhu D K. Radiation transport analysis of emission spectroscopic measurements in the plenum region of the NASA IHF arc jet facility[R]. AIAA-2014-2489, 2014.
    [14]
    Winter M W, Prabhu D K, Raiche G A, et al. Emission spectroscopic measurements with an optical probe in the NASA Ames IHF arc jet facility[R]. AIAA-2012-1016, 2012.
    [15]
    Nawaz A, Driver D M, Terrazas-Salinas I, et al. Surface catalysis and oxidation on stagnation point heat flux measurements in high enthalpy arc jets[R]. AIAA-2013-3138, 2013.
    [16]
    林鑫, 陈连忠, 董永晖, 等.发射光谱诊断电弧加热器漏水故障的试验研究[J].实验流体力学, 2016, 30(4):14-19. http://www.syltlx.com/CN/abstract/abstract10945.shtml

    Lin X, Chen L Z, Dong Y H, et al. Experimental study on leak detection of cooling water in arc heater based on emission spectroscopy[J]. Journal of Experiments in Fluid Mechanics, 2016, 30(4):14-19. http://www.syltlx.com/CN/abstract/abstract10945.shtml
    [17]
    张志成.高超声速气动热和热防护[M].北京:国防工业出版社, 2003.
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Figures(7)

    Article Metrics

    Article views (195) PDF downloads(3) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return