Zhang Hong, Li Jie, Tian Shuqing. Investigation on full-coverage film cooling effectiveness of turbine vane with exit Mach number from 0.81 to 1.01[J]. Journal of Experiments in Fluid Mechanics, 2016, 30(3): 47-52. doi: 10.11729/syltlx20150095
Citation: Zhang Hong, Li Jie, Tian Shuqing. Investigation on full-coverage film cooling effectiveness of turbine vane with exit Mach number from 0.81 to 1.01[J]. Journal of Experiments in Fluid Mechanics, 2016, 30(3): 47-52. doi: 10.11729/syltlx20150095

Investigation on full-coverage film cooling effectiveness of turbine vane with exit Mach number from 0.81 to 1.01

doi: 10.11729/syltlx20150095
  • Publish Date: 2016-06-25
  • Heat transfer coefficient and film cooling effectiveness are investigated on a turbine vane employing the transient thermal couple technique.There are 1 3 rows of film cooling holes placed on the test blade.The cooling gas through film holes is supplied by two plenums,with mass flow ratio of 5.06% in the first plenum and 1.14% in the second.To match the real engine operating condition,the range of the inlet Reynolds number and the exit Mach number of the cur-rent experiment are 1.7×105~5.7×105 and 0.81~1.01,respectively.Heat transfer coefficient distribution is obtained,and effects of Reynolds number and Mach number to film cooling effec-tiveness distribution are investigated.The results show that heat transfer coefficient and film cooling effectiveness are higher in the near hole region.Film cooling effectiveness increases as in-let Reynolds number increases,especially on the pressure side and suction side,while the effect of exit Mach number to film cooling effectiveness is not obvious.
  • loading
  • 加载中

Catalog

    通讯作者: 陈斌, bchen63@163.com
    • 1. 

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (134) PDF downloads(3) Cited by()
    Proportional views
    Related

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return